reactive (Q) powers suppliedby the transformer. They also measured the RMS values of the transformer input current and theload current (RLC load).Exercise 4: In this exercise, students used the Simulink toolboxes to simulate a three-phasepower system that includes a transformer and several loads as shown in Figure 2. Specificationsincluded: A balanced Y-connected source with Vphase-to-phase voltage of 120 Vrms, 60 Hz,connected to a three-phase transformer with a turns ration n = 2. The output of the transformersupplies power to two separate loads. The first load is a -connected three-phase series RLCload of PL = 10 kW, QL = 200 VARs, and QC = 100 VARs. The second load is a three-phaseseries RLC load with P = 10 kW, QL = 200 VARs, and QC = 100