Asee peer logo
Well-matched quotation marks can be used to demarcate phrases, and the + and - operators can be used to require or exclude words respectively
Displaying all 5 results
Collection
2010 ASEE Zone 1 Conference
Authors
Daniel Ruscansky; David Vecchione; Ryan Foley; Shankar Krishnan; Mansour Zenouzi
. . . . . Q m = Q con + Q cov + Q rad + Q evp . Q m = 0.0533(m)( p ) + 1.64 = 1.802WResults:Modeling the system as a second order approximation, the time it takes for the temperature toreach steady state, and the percent overshoot can be calculated. Shown below in Figure 2 is amodel of the second order system. Figure 2 ~ Second Order Approximation of Incubator Temperature Control Figure 2 ~ Temperature Control Model OutputThe overshoot of temperature will be adjusted to be as close to 0% as possible. This will be donewith the design of a controller.The heat loss per unit area of the housing of the incubator system was calculated to be 1.56 .The total surface
Collection
2010 ASEE Zone 1 Conference
Authors
Linfeng Zhang; Nicolae Gari; Xingguo Xiong; Junling Hu; Lawrence V. Hmurcik P.E.
of the MG components areimplemented as threads in the simulation. The energy generator, energy storage, and loadsperiodically update the manager about their status. Fig. 1. The structure of a smart grid with four micro- grids For the economic return on the investment of an individual MG, a performance metric foreach MG is proposed. An overall performance index of each MG can be calculated as: 4 Q = w1 F + w2 E + w3 S (1) F is a cost index of electricity, E is an environmental effect index due to atmosphericemissions, and S is a satisfaction index of the power
Collection
2010 ASEE Zone 1 Conference
Authors
Onesmo Ogore; Kushal Sherpa; Caleb Baron; Mansour Zenouzi; Shankar Krishnan
Air Bubble Detector Heparin Pump R Arterial [I] Blood [II] Blood F Unfiltered Blood Q P Pump Membrane Blood to Dialyzer E [III] Diaysate [IV
Collection
2010 ASEE Zone 1 Conference
Authors
R. Radharamanan; Jeng-Nan Juang
q = max (2) MS E n 2 Table 1: Airspeed data collected from experiments Fan Speed (V) Channel Height (mm) Airspeed (cm/s) 12 2 8.50 11 2 6.00 10 2 3.83 9 2 3.00 8 2 2.83
Collection
2010 ASEE Zone 1 Conference
Authors
Paul C. King; Gerarda M. Shields
and the Faculty Commons.REFERENCESColon, K., “The Global Achievement Gap: Q&A with Tony Wagner,” Harvard Graduate School ofEducation, August 20, 2008.“Chancellor Launches NYC21C Initiative at NYC iSchool,” New York City Department of Education,http://schools.nyc.gov/Offices/mediarelations/NewsandSpeeches/2008-2009/20090512_ischool.htm, lastaccessed March 12, 2010.Gibbs, N., “Generation Next,” Time, New York, March 22, 2010.Wagner, T., Global Achievement Gap, 1st Ed., Basic Books, New York, 2008. Page 8 of 8